APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today?s high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.
APC NetShelter Rack PDU Advanced Power Distribution Unit (rack mountable) switched AC 400/415 V 17.3 kW 17300 VA 3-phase Ethernet 10/100/1000 input: IEC 60309 530P6 connectors output: 48 (24 x IEC 60320 C13/C15
APC NetShelter Rack PDU Advanced, Switched, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309. PDU types: Switched, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 24 AC outlet(s), AC outlet types: C13 coupler, C15 coupler, C19 coupler, C21 coupler, Power plug: IEC 60309. Nominal input voltage: 240V, Maximum current: 24 A, AC input frequency: 50 - 60 Hz. Certification: CE, CSA C22.2 No 62368-1, EN 62368-1, FCC part 15 subpart B, UKCA, UL 62368-1. Width: 56 mm, Depth: 75 mm, Height: 1780 mm
Technical details | |
Ports & interfaces | |
AC outlets quantity | 24 AC outlet(s) |
AC outlet types | C13 coupler, C15 coupler, C19 coupler, C21 coupler |
Power plug | IEC 60309 |
Weight & dimensions | |
Width | 56 mm |
Depth | 75 mm |
Height | 1780 mm |
Weight | 9.6 kg |
Power | |
Nominal input voltage | 240V |
Maximum current | 24 A |
AC input frequency | 50 - 60 Hz |
Nominal output voltage | 240 V |
Load capacity | 17300 VA |
Maximum input current per phase | 30 A |
Maximum total current draw per phase | 24 A |
Operational conditions | |
Operating temperature (T-T) | -5 - 60 °C |
Storage temperature (T-T) | -25 - 65 °C |
Operating relative humidity (H-H) | 5 - 95% |
Storage relative humidity (H-H) | 5 - 95% |
Operating altitude | 0 - 3048 m |
Non-operating altitude | 0 - 15240 m |
Packaging data | |
Package weight | 12.6 kg |
Package width | 262 mm |
Package depth | 132 mm |
Package height | 1980 mm |
Certificates | |
Certification | CE, CSA C22.2 No 62368-1, EN 62368-1, FCC part 15 subpart B, UKCA, UL 62368-1 |
Management features | |
Packaging content | |
Battery | |
Other features | |
Design | |
PDU types | Switched |
Rack capacity | 0U |
Type | Three-phase |
Mounting | Vertical |
Product colour | Black |
Display | LCD |
On/off switch | No |
Features | |
Daisy chain | Yes |
Logistics data | |
Total carbon footprint (kg of CO2e) | 3861.19 |
Supplier features | |
Sustainability | |
Safety regulation & standards |